Print this page Email this page
Users Online: 632
Home About us Editorial board Search Browse articles Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2022  |  Volume : 11  |  Issue : 1  |  Page : 2

The effect of white noise exposure on anxiety and hemodynamic parameters of operating room staff


1 Department of Operating Room, School of Nursing, Abadan University of Medical Sciences, Abadan, Iran
2 Research Center of Addiction and Behavioral Sciences, Department of Anesthesia and Operation Room, Paramedical Faculty, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
3 Department of Occupational Health, School of Public Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
4 Department of Biostatistics and Epidemiology, Research Center of Prevention and Epidemiology of Non-Communicable Disease, School of Public Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran

Correspondence Address:
Dr. Hamid Mirhosseini
School of Paramedical Sciences, Shahid Sadoughi University of Medical Sciences, Yazd
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijehe.ijehe_6_21

Rights and Permissions

Aim: Anxiety reduces performance at work. Anxiety is significantly prevalent among medical staff in general, and especially operating room staff. The present study was an attempt to investigate the effect of suction-induced white noise on anxiety and hemodynamic parameters of operating room staff during cesarean section. Materials and Methods: The present study was a crossover, single-blind clinical trial on 29 scrub staff during cesarean section. The subjects were assigned once to the control group and once to the intervention group with a 10-day washout period. In the intervention group, the suction machine was left on during surgery for 3 days in a row, but in the control group, the suction machine was switched off in idle times to make sure that noise exposure time would remain below 30 min. Hemodynamic parameters of subjects were measured on the last day immediately after surgery, and the Spielberger State-Trait Anxiety Inventory was used to measure the level of anxiety. SPSS 22 software and linear mixed model were used to analyze the collected data. Results: The control and intervention groups were not significantly different in terms of hemodynamic parameters, anxiety as well as the carryover-crossover effects (P > 0.05). A significant negative correlation was observed between anxiety score and age of the subjects (P < 0.05). Conclusions: Suction-induced white noise has no effect on anxiety and hemodynamic parameters of operating room staff. Adaptation to workplace noises can reduce the adverse effects of noise.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1826    
    Printed26    
    Emailed0    
    PDF Downloaded24    
    Comments [Add]    
    Cited by others 1    

Recommend this journal